Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.534
Filter
1.
Chinese Journal of Biologicals ; (12): 65-71, 2024.
Article in Chinese | WPRIM | ID: wpr-1006201

ABSTRACT

@#Objective To develop and verify a whole column imaging detection-capillary isoelectric focusing(WCID-CIEF)method for the determination of isoelectric point(pI)of pertactin(PRN).Methods The WCID-CIEF method for the determination of PRN antigen was developed by optimizing the parameters such as the focusing time and final concentration of samples in the WCID-CIEF process,and verified for the specificity,accuracy,repeatability,intermediate precision,durability and inter-batch consistency.Results The optimal focusing time of WCID-CIEF for the determination of PRN antigen pI was 1 min at 1 500 V and 3 min at 3 000 V. The optimal final concentration of PRN antigen was 300 μg/mL. The PRN antigen pI was about 6. 035,and the blank matrix showed no interference peak in the position of each peak of antigen. The method had good specificity,accuracy,repeatability,intermediate precision,durability and consistency among batches.Conclusion The developed WCID-CIEF method is suitable for the pI detection and charge heterogeneity analysis of PRN antigen,which can provide basis for the characterization of PRN antigen and reference for the quality control in the process of development and production of related vaccines.

2.
Chinese Journal of Biologicals ; (12): 1-7+16, 2024.
Article in Chinese | WPRIM | ID: wpr-1006189

ABSTRACT

@#Objective To analyze the trend of the hemagglutinin(HA) and ovalbumin contents in the lot release of influenza virus split vaccines in 2021,and evaluate the quality and quality control level of the vaccines.Methods The HA and ovalbumin content data of influenza virus split vaccines from two domestic enterprises in 2021 were collected and collated. The mean value and standard deviation were calculated according to the first 40 batches of data of the enterprise in the year,and the warning limit and action limit were established. The trend analysis of the above indexes was carried out to evaluate the stability and consistency of the product quality of the enterprise. Statistical data comparison and consistency analysis were made between the test results of the batch inspected by the lot release institution and the results of the enterprise.Results Through the retrospective data analysis of quadrivalent influenza virus split vaccines from two vaccine enterprises A and B,it was found that the content of H1N1 subtype HA and ovalbumin in the two enterprises and the content of Bv HA in the B enterprise had out of trend(OOT)situations,while the trend of other items was stable. The results of paired student's t test or Wilcoxon signed-rank test of the samples inspected by the lot release institution showed that except Bv subtype HA(t = 1. 094 and 0. 742 respectively)and ovalbumin(w =-64 and 36 respectively)contents showed no statistically significant difference(P > 0. 05),the HA contents of H1N1(t = 3. 862,w = 232),H3N2(t = 8. 225 and3. 473 respectively)and By(t = 5. 616 and 4. 934 respectively)of the two enterprises had significant differences(P <0. 05). The results of enterprises were generally higher than the lot release institution. Bland-Altman test analysis found that the consistency between the test data of enterprise A's HA content and the data of the lot release institution was better than that of enterprise B.Conclusion The stability and consistency of data trends of active ingredients and main impurity ingredients of quadrivalent influenza virus split vaccine batches in 2021 were generally good. The trend analysis can identify potential problems in vaccine production,and enterprises should carefully implement trend analysis and effectively monitor the product quality of vaccines.

3.
Journal of Pharmaceutical Practice ; (6): 1-5, 2024.
Article in Chinese | WPRIM | ID: wpr-1005419

ABSTRACT

Sprays have gained significant attention and widespread use due to their numerous advantages, including rapid action, safety, and convenience. They are widely used in various fields such as dermatology, respiratory disease treatment, wound repair, and central nervous system targeted drug delivery. With the in-depth research of new drugs and modern pharmaceutics, the development ideas of sprays are more diverse, and the application scenarios are increasingly extensive. In this review the clinical application status of sprays and the latest research progress were summarized. Then the quality control parameters were briefly introduced,which provided reference for the research and development of sprays.

4.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 12-20, 2024.
Article in Chinese | WPRIM | ID: wpr-1005248

ABSTRACT

In the quality control of Chinese medicine, the detection of active components and toxic and harmful components are two important links. Although conventional methods such as high performance liquid chromatography and liquid chromatography-mass spectrometry can accurately quantify the above substances, they have shortcomings such as complicated operation, high costs, inability of detection at any time, difficult detection of insoluble and macromolecular substances. Enzyme-linked immunosorbent assay (ELISA) can adsorb antigens or antibodies on the surface of solid carriers and realize qualitative or quantitative analysis of targets by using the specific reactions of antigens and antibodies. This method is praised for the simple operation, high sensitivity, strong specificity, simple requirements for experimental equipment, a wide application range, and low costs. In recent years, ELISA has been widely used in the quality control of Chinese medicine, especially in the content determination of mycotoxins represented by aflatoxin and the qualitative and quantitative analysis of active components. ELISA plays an increasingly important role with its unique advantages, providing new methods and ideas for the rapid quality examination of large quantities of Chinese medicines. This paper reviews the research progress in ELISA for the quality control of Chinese medicine in recent years and prospects its technical development and application prospects, aiming to provide reference and research ideas for further using this method to ensure the quality, safety, and controllability of Chinese medicine.

5.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 255-263, 2024.
Article in Chinese | WPRIM | ID: wpr-999183

ABSTRACT

Diabetic peripheral neuropathy(DPN) is a neurodegenerative disease of diabetes mellitus involving peripheral nervous system damage, which is characterized by axonal degenerative necrosis, Schwann cell apoptosis and demyelination of nerve myelin sheath as the main pathological features, this disease is highly prevalent and is a major cause of disability in diabetic patients. Currently, the pathogenesis of DPN may be related to oxidative stress, inflammatory response, metabolic abnormality, and microcirculation disorder. The treatment of DPN in modern medicine mainly starts from controlling blood glucose, nourishing nerves and improving microcirculation, which can only alleviate the clinical symptoms of patients, and it is difficult to fundamentally improve the pathological damage of peripheral nerves. Mitochondrial quality control refers to the physiological mechanisms that can maintain the morphology and functional homeostasis of mitochondria, including mitochondrial biogenesis, mitochondrial dynamics, mitochondrial oxidative stress and mitochondrial autophagy, and abnormal changes of which may cause damage to peripheral nerves. After reviewing the literature, it was found that traditional Chinese medicine(TCM) can improve the low level of mitochondrial biogenesis in DPN, maintain the balance of mitochondrial dynamics, inhibit mitochondrial oxidative stress and mitochondrial autophagy, and delay apoptosis of Schwann cells and neural axon damage, which has obvious effects on the treatment of DPN. With the deepening of research, mitochondrial quality control may become one of the potential targets for the research of new anti-DPN drugs, therefore, this paper summarized the research progress of TCM in treating DPN based on four aspects of mitochondrial quality control, with the aim of providing a theoretical research basis for the discovery of new drugs.

6.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535404

ABSTRACT

Introducción: La calidad de los datos facilita garantizar la fiabilidad de los estudios observacionales. Objetivo: Describir el aseguramiento y el control de calidad para mantener la fiabilidad y la validez del dato en un estudio de cohorte. Métodos: Presentar el manejo de datos implementado dentro de un seguimiento de enfermos renales crónicos cuya exposición fue un programa de protección renal comparado con el tratamiento convencional y su asociación con desenlaces clínicos. Se evaluó el cambio en la frecuencia de errores después de implementar el plan y la reproducibilidad del ingreso de registros a las bases de datos. Resultados: Se documentó una disminución progresiva en los errores cometidos en la captación de datos. El valor de Kappa entre los recolectores de la información para las variables clínicas más importantes fue 0,960 para la depuración de creatinina 150 mg/dL; 0,730 para la alteración del sedimento urinario; 0,956 para la asignación de estadio al ingreso. Los coeficientes de correlación intraclase para la identificación de las cifras de presión arterial sistólica fue 0,996; para la de presión arterial diastólica 0,993 y para los niveles de creatinina sérica al diagnóstico 0,995. Discusión: La calidad de los datos comienza con el reconocimiento de los retos y dificultades que implica su responsable captación, de ahí el aporte de la estandarización de los procesos y el personal que los lleve a cabo en forma idónea. Estudios evidencian que muchos procesos de mejora surgen en el desarrollo de la investigación sin protocolos preestablecidos. Conclusión: La reducción en la proporción y el tipo de error durante el proceso de captación de datos se debe a su identificación temprana y la corrección de instructivos, del instrumento de control de diligenciamiento y de la capacitación continua del personal. El análisis mostró una buena concordancia interevaluador.


Introduction: Data quality makes it easier to ensure that observational studies are reliable. Objective: To describe assurance and quality control to maintain data reliability and validity in a cohort study. Methodology: We present the data management strategies implemented in a study that followed patients of chronic kidney disease who were in a renal protection program and compared them with those undergoing conventional treatment to observe its association with clinical outcomes. We assessed the changes in error frequency after implementing the plan along with the reproducibility of the strategies for entering records into the databases. Results: We documented a progressive decrease of data collection errors. The Kappa values among data collectors for the most important variables were: 0.960 for creatinine clearance 150 mg/dl; 0.730 for urinary sediment alteration and 0.956 for stage allocation upon admission. The intraclass correlation coefficient for the identification of systolic blood pressure was 0.996; for diastolic blood pressure, the coefficient was 0.993 and for serum creatinine levels at diagnosis, the value was 0.995. Discussion: Data quality begins with the recognition of the challenges and difficulties involved in responsible data collection, hence the contribution of standardized processes and personnel to carry them out in a suitable manner. Studies show that many improvement processes arise in the development of research without pre-established protocols. Conclusion: The reduction in error ratio and type during the data collection process are the result of the early identification of erroneously entered or missing data, the correction of the guidelines for completing forms as well as of the instruments for detecting errors and continuous training of the staff. The analysis showed good inter-rater reliability.

7.
Rev. mex. anestesiol ; 46(2): 87-92, abr.-jun. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1508624

ABSTRACT

Resumen: Introducción: El diferimiento quirúrgico desde el inicio de la pandemia COVID-19 representa un riesgo para la salud de los pacientes y un reto para las instituciones sanitarias. La métrica de indicadores de productividad en quirófano, como la tasa de diferimiento quirúrgico, nos brindará información para planear estrategias basadas en evidencia científica que nos permitan mejorar la calidad de la atención. Objetivo: Determinar la tasa de diferimiento quirúrgico durante la pandemia COVID-19. Material y métodos: Se realizó un estudio, retrospectivo, descriptivo y transversal en el que se analizaron 297 pacientes cuyas cirugías fueron diferidas durante el período comprendido del 11 de marzo de 2020 al 10 de marzo de 2021. Para el análisis de variables se efectuó estadística descriptiva, utilizando medidas de tendencia central y dispersión, frecuencias simples y proporciones. Adicionalmente se realizó un diagrama de Pareto. La información fue procesada con SPSS v-25.0. Resultados: La proporción de diferimiento fue de 7.34%; 20.92% de las causas fueron atribuidas al paciente, 31.65% a causas médicas y 47.49% fueron logístico-administrativas. Conclusión: Las causas de diferimiento quirúrgico establecidas son evitables y revelan fracasos en los procesos logístico-administrativos que requieren planes de mejora continua.


Abstract: Introduction: Surgical deferral since the beginning of the COVID-19 pandemic represents a risk to the health of patients and a challenge for health institutions. The metric of productivity indicators in the operating room, such as the surgical deferral rate, will provide us with information to plan strategies based on scientific evidence that allow us to improve the quality of care. Objective: To determine the surgical deferral rate during the COVID-19 pandemic. Material and methods: A retrospective, descriptive and cross-sectional study was carried out in which 297 patients whose surgeries were deferred during the period from March 11, 2020 to March 10, 2021 were analyzed. Descriptive statistics were employed, using measures of central tendency and dispersion, simple frequencies and proportions. Additionally, a Pareto diagram was made. The information was processed with SPSS v-25.0. Results: The deferral rate was 7.34%. 20.92% of the causes were attributed to the patient, 31.65% to medical causes and 47.49% logistic-administrative. Conclusion: The established causes of surgical deferral are avoidable and reveal failures in the logistical-administrative processes that require continuous improvement plans.

8.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535126

ABSTRACT

Objetivo: Optimizar el control interno de calidad de RT-PCR en tiempo real para detección cualitativa de SARS-CoV-2, utilizando los valores Cq de controles negativos y positivos. Material y método: Estudio prospectivo-longitudinal. La muestra estuvo constituida por 143 valores Cq para los controles negativos de alicuotado y extracción, así como para el control positivo. Se analizó la distribución normal de los valores Cq mediante la prueba de Anderson-Darling (AD) y se aplicaron pruebas de aleatoriedad. Se calculó límites de control a partir de 51 valores Cq, para luego, mediante gráficas de control, monitorizar 92 valores Cq obtenidos desde noviembre del 2020 hasta marzo del 2021. Se evaluó aceptación de lote e índices Cpk como indicadores de optimización. Los cálculos se hicieron con el programa Minitab. Resultados: Se aceptaron los lotes de valores Cq y se obtuvieron índices Cpk superiores a 1.33 para los tres tipos de control. Discusión: No existen estudios publicados que apliquen control estadístico de calidad a la detección cualitativa de SARS-CoV-2. Conclusiones: Es posible utilizar los valores Cq de los controles para optimizar el control interno de calidad de RT-PCR en tiempo real para detección cualitativa de SARS-CoV-2, como si se tratara de una técnica de tipo cuantitativo.


Objective: To optimize the internal quality control of real-time RT-PCR for the qualitative detection of SARS-CoV-2, using the Cq values ​​of negative and positive controls. Material and method : Prospective-longitudinal study. The sample consisted of 143 Cq values for the negative aliquot and extraction controls, as well as for the positive control. The normal distribution of Cq values ​​was analyzed using the Anderson-Darling (AD) test and randomness tests were applied. Control limits were calculated from 51 Cq values, and then, using control charts, to monitor 92 Cq values ​​obtained from November 2020 to March 2021. Lot acceptance and Cpk indices were evaluated as optimization indicators. The calculations were made with the Minitab program. Results: The batches of Cq values ​​were accepted and Cpk indices higher than 1.33 were obtained for the three types of control. Discussion : There are no published studies that apply statistical quality control to the qualitative detection of SARS-CoV-2. Conclusions : It is possible to use the Cq values ​​of the controls to optimize the internal quality control of real-time RT-PCR for qualitative detection of SARS-CoV-2, as if it were a quantitative technique.

9.
Rev. panam. salud pública ; 47: e162, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1536661

ABSTRACT

ABSTRACT Objective. To evaluate the screening of blood samples for infectious disease markers at laboratories and blood banks in Latin America per the findings of an External Quality Assessment Program (EQAP). Methods. This qualitative analysis used data from the EQAP coordinated by the Fundação Pro Sangue Hemocentro de São Paulo with the support of the Pan American Health Organization to assess the performance of blood screening for infectious diseases from 2014 to 2018 in Latin America. Each participating laboratory or blood bank received an identical blind panel with 24 blood samples with variable reactivity for all the screening parameters. Panels were processed at each participating facility and results were returned to the Fundação Pro Sangue Hemocentro de São Paulo for individual and joint analyses. Two types of discrepant results were potential failures: false positive results (FPRs) and false nonreactive results (FNRRs). Results. A total of 23 136 samples were evaluated. Global rates of FPR, FNRR, and concordant results were 0.3%, 1.0% and 98.7%, respectively. Seven FNRRs were found for HBsAg (1.0%), 12 for syphilis (2.6%), and 21 for Chagas disease (2.9%). No FNRRs were found for the HIV, HCV, and HTLV viruses. The average accuracy of all the laboratories and blood banks participating in the EQAP during the study period was 99.5% (standard deviation, 0.5%). Conclusion. The findings of this qualitative analysis are positive for blood safety in Latin America, with an average accuracy of 99.5% among the participating laboratories and blood banks. This report reflects an important improvement in blood bank serological screening EQAP-PAHO report since the 2003.


RESUMEN Objetivo. Evaluar el tamizaje de muestras de sangre en las que se analizan marcadores de enfermedades infecciosas en laboratorios y bancos de sangre de América Latina según los resultados de un programa de evaluación externa de la calidad (EQAP, por su sigla en inglés). Métodos. Este análisis cualitativo utilizó datos del EQAP —coordinado por la Fundação Pro Sangue Hemocentro de São Paulo con el apoyo de la Organización Panamericana de la Salud— para evaluar la eficacia del tamizaje sanguíneo para la detección de enfermedades infecciosas que se realizó entre el 2014 y el 2018 en América Latina. Cada laboratorio o banco de sangre participante recibió un panel idéntico para análisis a ciegas compuesto por 24 muestras de sangre con reactividad variable para todos los parámetros del tamizaje. Los paneles se procesaron en cada establecimiento participante y los resultados se enviaron a la Fundação Pro Sangue Hemocentro de São Paulo donde se realizaron análisis individuales y conjuntos. Había dos tipos de resultados discrepantes que eran posibles fallas del tamizaje: los positivos falsos (PF) y los negativos falsos (NF). Resultados. En total se evaluaron 23 136 muestras. Las tasas generales de PF, NF y resultados concordantes fueron, respectivamente, del 0,3%, 1,0% y 98,7%. Se obtuvieron siete NF en casos de HBsAg (1,0%), 12 en casos de sífilis (2,6%) y 21 en casos de enfermedad de Chagas (2,9%). No se obtuvieron NF en casos de infección por virus del VIH, el VHC o el VLTH. La precisión promedio de todos los laboratorios y bancos de sangre participantes en el EQAP durante el periodo de estudio fue del 99,5% (desviación típica: 0,5%). Conclusión. Los resultados de este análisis cualitativo son positivos en lo referente a la seguridad sanguínea en América Latina, con una precisión promedio del 99,5% entre los laboratorios y bancos de sangre participantes. Este informe refleja la considerable mejora del tamizaje serológico que se realiza en los bancos de sangre, en comparación con los resultados del informe del EQAP que contó con el apoyo de la OPS y se publicó en el 2003.


RESUMO Objetivo. Avaliar a triagem de marcadores de doenças infecciosas em amostras de sangue realizada em laboratórios e bancos de sangue da América Latina de acordo com os resultados de um Programa Externo de Avaliação de Qualidade (EQAP, na sigla em inglês). Métodos. Esta análise qualitativa usou dados do EQAP coordenado pela Fundação Pró-Sangue Hemocentro de São Paulo, com o apoio da Organização Pan-Americana da Saúde, para avaliar o desempenho da triagem de sangue quanto a doenças infecciosas no período de 2014 a 2018 na América Latina. Cada laboratório ou banco de sangue participante recebeu um painel cego idêntico com 24 amostras de sangue de reatividade variável para todos os parâmetros de triagem. Os painéis foram processados em cada estabelecimento participante e os resultados foram devolvidos à Fundação Pró-Sangue Hemocentro de São Paulo para análises individuais e conjuntas. Dois tipos de resultados discrepantes representavam falhas em potencial: resultados falso-positivos e resultados falso-negativos (não reativos). Resultados. Foram avaliadas 23.136 amostras. As taxas globais de resultados falso-positivos, falso-negativos e concordantes foram de 0,3%, 1,0% e 98,7%, respectivamente. Foram encontrados sete resultados falso-negativos para HBsAg (1,0%), 12 para sífilis (2,6%) e 21 para doença de Chagas (2,9%). Não houve resultados falso-negativos para os vírus HIV, HCV e HTLV. A acurácia média de todos os laboratórios e bancos de sangue que participaram do EQAP durante o período do estudo foi de 99,5% (desvio padrão de 0,5%). Conclusões. Os resultados desta análise qualitativa são positivos para a segurança do sangue na América Latina, com uma acurácia média de 99,5% entre os laboratórios e bancos de sangue participantes. Este relatório reflete uma melhoria importante na triagem sorológica dos bancos de sangue em relação aos resultados do relatório do EQAP apoiado pela OPAS que foi publicado em 2003.

10.
Arq. ciências saúde UNIPAR ; 27(10): 5918-5928, 2023.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1512858

ABSTRACT

O Limonium brasiliense (Boiss.) Kuntze (Plumbaginaceae), chamado popularmente de baicuru ou guaicuru é uma erva perene presente em todo litoral sul do Brasil, sendo indicada tradicionalmente para síndrome pré-menstrual e distúrbios menstruais. Essas atividades são atribuídas à presença dos polifenóis concentrados em seus rizomas, que também apresentam atividades bacteriostáticas, antioxidantes, antivirais e anti-inflamatórias. No desenvolvimento de formulações feitas a partir da droga vegetal são necessários testes de controle de qualidade durante todo o processo a fim de garantir a segurança, eficácia e qualidade da matéria-prima até sua formulação final. As metodologias utilizadas no desenvolvimento deste trabalho foram de análises físico-químicas para o controle de qualidade, análises quantitativas para determinação do teor de polifenóis totais e, por fim, uma análise comparativa entre os resultados obtidos no ano da coleta do material vegetal (2010) e das mesmas características após 13 anos da coleta, utilizando amostras do L. brasiliense com a presença de fungos ou sem nos rizomas. Sendo assim, este trabalho teve como objetivo realizar o controle de qualidade comparativo dos rizomas de Limonium brasiliense coletados em 2010 em relação ao teor de polifenóis totais e de umidade em 2023. Os resultados obtidos evidenciaram a produção de polifenóis pelos fungos na amostra contaminada, além de mostrarem a qualidade de armazenagem da droga vegetal. Com isso, foi possível concluir que o teor de polifenóis totais da amostra com fungo aumentou após 13 anos da coleta, e que neste interim não houve mudanças no teor de umidade da amostra sem fungo, garantindo sua qualidade no desenvolvimento de formulações ou pesquisas futuras.


Limonium brasiliense (Boiss.) Kuntze (Plumbaginaceae), popularly called baicuru or guaicuru, is a perennial herb present throughout the southern coast of Brazil, traditionally indicated for premenstrual syndrome and menstrual disorders. These activities are attributed to the presence of polyphenols concentrated in its rhizomes, which also have bacteriostatic, antioxidant, antiviral and anti-inflammatory activities. When developing formulations made from plant-based drugs, quality control tests are necessary throughout the process to ensure the safety, efficacy and quality of the raw material until its final formulation. The methodologies used in the development of this work were physical-chemical analyzes for quality control, quantitative analyzes to determine the total polyphenol content and, finally, a comparative analysis between the results obtained in the year the plant material was collected (2010) and the same characteristics after 13 years of collection, using samples of L. brasiliense with or without the presence of fungi in the rhizomes. Therefore, this work aimed to carry out comparative quality control of Limonium brasiliense rhizomes collected in 2010 in relation to the content of total polyphenols and moisture in 2023. The results obtained showed the production of polyphenols by fungi in the contaminated sample, in addition to show the storage quality of the plant drug. With this, it was possible to conclude that the total polyphenol content of the sample with fungus increased after 13 years of collection, and that in the meantime there were no changes in the moisture content of the sample without fungus, guaranteeing its quality in the development of formulations or future research.


Limonium brasiliense (Boiss.) Kuntze (Plumbaginaceae), popularmente llamada baicuru o guaicuru, es una hierba perenne presente en toda la costa sur de Brasil, tradicionalmente indicada para el síndrome premenstrual y trastornos menstruales. Estas actividades se atribuyen a la presencia de polifenoles concentrados en sus rizomas, que también tienen actividades bacteriostáticas, antioxidantes, antivirales y antiinflamatorias. Cuando se desarrollan formulaciones elaboradas a partir de medicamentos de origen vegetal, son necesarios ensayos de control de calidad durante todo el proceso para garantizar la seguridad, eficacia y calidad de la materia prima hasta su formulación final. Las metodologías utilizadas en el desarrollo de este trabajo fueron análisis físico- químicos para control de calidad, análisis cuantitativos para determinar el contenido de polifenoles totales y, finalmente, un análisis comparativo entre los resultados obtenidos en el año de recolección del material vegetal (2010) y el mismas características después de 13 años de colecta, utilizando muestras de L. brasiliense con o sin presencia de hongos en los rizomas. Por lo tanto, este trabajo tuvo como objetivo realizar un control de calidad comparativo de los rizomas de Limonium brasiliense recolectados en 2010 en relación al contenido de polifenoles totales y humedad en 2023. Los resultados obtenidos mostraron la producción de polifenoles por hongos en la muestra contaminada, además de mostrar la calidad de almacenamiento de la droga vegetal. Con esto se pudo concluir que el contenido total de polifenoles de la muestra con hongos aumentó después de 13 años de colecta, y que mientras tanto no hubo cambios en el contenido de humedad de la muestra sin hongos, garantizando su calidad en el desarrollo. de formulaciones o investigaciones futuras.

11.
Braz. J. Pharm. Sci. (Online) ; 59: e23171, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520308

ABSTRACT

Abstract Albendazole is an anthelmintic drug commonly used in parenchymal neurocysticercosis and cystic echinococcosis. The aim of this study was to explore whether disparities in the dissolution profiles of albendazole products lead to significant differences in pharmacokinetic parameters. Three generic products and the innovator were evaluated in vitro. Quality control tests were performed, and dissolution profiles were obtained according to the Mexican Pharmacopeia. Although all products passed the quality control tests, none of the generic products complied with the similarity factor (f 2). The product with the lowest f 2 value in respect to the reference was chosen for in vivo evaluation. The study was carried out in 12 healthy volunteers who received 400 mg of the generic or reference product according to a crossover design. No significant differences were found in Cmax and AUC for albendazole and its main metabolite, albendazole sulfoxide, between products. Two absorption peaks were observed in the pharmacokinetic profile, and a population (22%) with different absorption rates and delay time for the the second peak was found. Based on the results, due to the high variability in the absorption process the differences observed in vitro could not be observed in vivo.

12.
Article in Spanish | LILACS, CUMED | ID: biblio-1442248

ABSTRACT

Las medidas de bioseguridad son el conjunto de conductas mínimas a ser adoptadas, a fin de reducir o eliminar los riesgos para el personal, la comunidad y el medio ambiente. Los laboratorios veterinarios manipulan materiales biológicos que pueden suponer riesgos biológicos tanto para los animales como para el hombre, por lo que los profesionales de estos laboratorios están expuestos a una variedad de riesgos relacionados con su trabajo que pueden afectar su salud. El objetivo de este trabajo fue evaluar el riesgo en el control de calidad de las vacunas virales mediante el uso del método BIOGAVAL, una forma cómoda y fiable de evaluar el riesgo de exposición a agentes biológicos. El estudio se realizó en la Unidad Empresarial de Base Control de la Calidad de la Empresa Productora de Vacunas Virales y Bacterianas el cual pertenece a LABIOFAM. La muestra de estudio estuvo conformada por 18 trabajadores, distribuidos en tres áreas. En los resultados obtenidos para valores superiores a 12 del nivel de acción biológica se requiere la adopción de medidas preventivas para reducir la exposición en el caso de Avulavirus, Pestivirus y Coronavirus, mientras que para Alphavirus se requieren acciones correctoras inmediatas ya que representa una situación de riesgo intolerable(AU)


Biosafety measures are the set of minimum behaviors to be adopted, in order to reduce or eliminate risks to personnel, the community and the environment. Veterinary laboratories handle biological materials that can pose biological risks for both animals and humans, so that professionals in these laboratories are exposed to a variety of risks to their health related to their work. The objective of this work was to evaluate the risk in the quality control of viral vaccines through the use of BIOGAVAL method, a convenient and reliable way to assess the risk of exposure to biological agents. The study was carried out in the Base Business Unit Quality Control of the Production Company of Viral and Bacterial Vaccines which belongs to LABIOFAM. The study sample consisted was 18 workers, dispersed in three areas. For values above 12 of the biological action level, preventive measures are required to reduce exposure to Avulavirus, Pestivirus and Coronavirus, while for Alphavirus immediate corrective measures actions are required as it represents an intolerable risk situation(AU)


Subject(s)
Humans , Male , Female , Quality Control , Viral Vaccines/therapeutic use , Risk Assessment/methods , Containment of Biohazards/standards
13.
Article in Spanish | LILACS, CUMED | ID: biblio-1521942

ABSTRACT

Introducción: En Cuba, se desarrolló un medio de cultivo cromogénico y fluorogénico, para la detección, aislamiento y diferenciación de Salmonella de otras bacterias Gram negativas. El método que emplea el medio fue validado y su uso se adoptó en una norma cubana. El aseguramiento de la calidad y el control del rendimiento de los medios garantizan la confiabilidad de los resultados analíticos. La norma ISO 11133 establece criterios mínimos y métodos para evaluarlos. Objetivo: Evaluar los criterios de control de la calidad y de rendimiento de CromoCen® SALM, establecidos en la ISO 11133:2014/Amd.1:2018, para demostrar su fiabilidad para el análisis microbiológico de los alimentos de consumo humano. Métodos: Se evaluaron los indicadores de calidad físico-químicos de tres lotes y se definió un conjunto de ellos que caracteriza la calidad del medio antes y después de terminado, así como la consistencia entre lotes. Para el ensayo de rendimiento se seleccionaron 10 cepas de diferentes géneros. Se determinó la relación de productividad, el factor de selectividad y la electividad de CromoCen® SALM, según la ISO 11133. Resultados: La evaluación físico-química mostró una consistencia entre lotes en color, homogeneidad, apariencia del polvo y del medio preparado. Los valores de contenido de humedad y pH se encontraron dentro de los valores establecidos para este producto. La relación de productividad de CromoCen® SALM con respecto al agar triptona soya, fue superior al 50 por ciento, mientras que el factor de selectividad resultó de 4. Se demostró que en el medio de cultivo se puede diferenciar un grupo representativo de géneros microbianos de Salmonella. Conclusiones: CromoCen® SALM cumple con los requisitos de calidad establecidos para este tipo de productos, según la ISO 11133 vigente. La correcta formulación de los lotes, así como el cumplimiento de los requisitos de calidad aseguran el funcionamiento adecuado para lo que fue diseñado(AU)


Introduction: In Cuba, a new chromogenic and fluorogenic culture medium was developed for the detection, isolation and differentiation of Salmonella from other Gram negative bacteria. The method and medium were validated and their use was adopted as a Cuban standard. Quality assurance and control of media is essential and mandatory to ensure the reliability of the results of the analysis in which they are used. ISO 11133 establishes minimum criteria and methods to evaluate them. Objective: To evaluate the quality and performance criteria of CromoCen® SALM, as recommended in ISO 11133:2014/Amd.1:2018 to demonstrate its reliability for the microbiological analysis of food for human consumption. Methods: The physical-chemical quality indicators of three batches were evaluated and a group of them was defined to characterize its quality before and after finishing, as well to evaluate the consistency between batches. For the performance test, 12 strains of different genera were selected. The productivity ratio, the selectivity factor and the electivity of CromoCen® SALM were determined. Results: The physico-chemical evaluation showed a consistency between batches in color, homogeneity, appearance of the powder and of the prepared medium. The moisture content and pH values ranged within the established values for this product. The productivity ratio of CromoCen® SALM with respect to tryptone soy agar was greater than 50 percent, while the selectivity factor was 4. It was shown that in the culture medium a representative group of Salmonella microbial genera can be differentiated. Conclusions: CromoCen® SALM meets the quality requirements established for this type of products, according to the current ISO 11133 standard. The correct formulation of the batches, as well as the fulfillment of the quality requirements ensure the proper functionality and match the design purpose(AU)


Subject(s)
Humans , Quality Control , Total Quality Management/standards , Chromogenic Compounds/standards , Eating
14.
São Paulo med. j ; 141(5): e20211020, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1432464

ABSTRACT

ABSTRACT BACKGROUND: Carpal tunnel syndrome (CTS) is a common condition greatly affects patients' quality of life and ability to work. Systematic reviews provide useful information for treatment and health decisions. OBJECTIVE: This study aimed to assess the methodological quality of previously published systematic reviews on the treatment of CTS. DESIGN AND SETTING: Overview of systematic reviews conducted at the Brazilian public higher education institution, São Paulo, Brazil METHODS: We searched the MEDLINE and Cochrane Library database for systematic reviews investigating the treatment of CTS in adults. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and measurement tool to assess systematic reviews (AMSTAR) were applied by two independent examiners. RESULTS: Fifty-five studies were included. Considering the stratification within the AMSTAR measurement tool, we found that more than 76% of the analyzed studies were "low" or "very low". PRISMA scores were higher when meta-analysis was present (15.61 versus 10.40; P = 0.008), while AMSTAR scores were higher when studies performed meta-analysis (8.43 versus 5.59; P = 0.009) or when they included randomized controlled trials (7.95 versus 6.06; P = 0.043). The intra-observer correlation demonstrated perfect agreement (> 0.8), a Spearman's correlation coefficient of 0.829, and an ICC of0.857. The inter-observer correlation indicated that AMSTAR was more reliable than PRISMA. CONCLUSION: Overall, systematic reviews of the treatment of CTS are of poor quality. Reviews with better-quality conducted meta-analysis and included randomized controlled trials. AMSTAR is a better tool than PRISMA because it has a better performance and should be recommended in future studies. REGISTRATION NUMBER IN PROSPERO: CRD42020172328 (https://www.crd.york.ac.uk/PROSPERO/display_record.php?ID=CRD42020172328)

15.
Chinese Journal of Radiological Medicine and Protection ; (12): 614-619, 2023.
Article in Chinese | WPRIM | ID: wpr-993133

ABSTRACT

Objective:To provide reference for establishing the testing method for quality control of neutron beam in boron neutron capture therapy (BNCT) equipment in China by testing the radiation characteristic parameters and dosimetry characteristic parameters of epithermal neutron beam in hospital neutron irradiator (IHNI).Methods:By comparing the uncertainties in the result of various test items with the deviation values recommended by the European Joint Research Center (EC-JRC), the feasibility of the relevant of testing method was analyzed and evaluated.Results:The uncertainty in epithermal neutron fluence rate was 2.7%. The uncertainty in ratio of thermal to epithermal neutron fluence rate was 3.1%. The uncertainty in ratio of fast neutron air kerma to epithermal neutron fluence rate was 9.3%. The uncertainty in ratio of gamma air kerma to epithermal neutron fluence rate was 8.7%. The uncertainty in spatial distribution of neutron fluence rate was 2.7%. The uncertainty in thermal neutron fluence rate in phantom was 1.8%. The uncertainty in neutron and gamma-ray dose rate in phantom was 17.1% and 4.0%, respectively.Conclusions:The uncertainty in neutron dose rate measurement result in phantom is higher, and further research is needed to improve the accuracy of the testing method. The uncertainty in the measurement result of other test items is lower, and the accuracy of the test result is expected to meet the allowable deviation value recommended by the European Joint Research Center, and the test method is feasible.

16.
Chinese Journal of Radiological Medicine and Protection ; (12): 63-67, 2023.
Article in Chinese | WPRIM | ID: wpr-993052

ABSTRACT

Objective:To analyze the conventional quality control result of Leksell Icon Gamma Knife cone-beam CT and evaluate long-term stability of cone-bem CT.Methods:QA TOOL Plus was used to verify the accuracy of cone-beam CT. The phantom Catphan 503 was scanned, and the image spatial resolution, contrast to noise ratio and homogeneity were analyzed.Results:The maximum deviation in image volume of cone-beam CT was 0.09-0.17 mm, which passed the accuracy test. At the scanning patterns with CT dose index of 2.5 and 6.3 mGy, the spatial resolution was very stable at 7 and 8 lp/cm respectively. The contrast noise ratio and uniformity meet the reference requirements.Conclusions:The conventional quality control results of Leksell Icon Gamma Knife cone-beam CT are stable in 12 months. In addition to referring to the manufacturer′s baseline value, the unified analysis and evaluation standard for Gamma Knife need to be further improved for the quality control of cone-beam CT.

17.
Journal of Chinese Physician ; (12): 691-694,699, 2023.
Article in Chinese | WPRIM | ID: wpr-992362

ABSTRACT

Objective:To investigate the effect of intravenous anesthesia on the detection rate of lesions in diagnostic gastroscopy.Methods:A total of 9 071 subjects who underwent diagnostic gastroscopy at the Digestive Endoscopy Center of Yangzhou University Affiliated Hospital from March 2021 to February 2022 were selected. Data were collected from the gastroscopy quality control system, including age, gender, examination physician, Helicobacter pylori infection, examination method, withdrawal time, number of images left, number of biopsies, biopsy site, gastroscopy diagnosis, pathological diagnosis, etc. They were divided into anesthesia group and general group based on the examination method, and propensity score matching (PSM) was performed on the two groups of subjects. Excluding confounding factors, the detection of lesion location and lesion type in two groups of subjects was analyzed; Simultaneously, univariate and multivariate logistic regression analysis was used to analyze the influencing factors of the detection rate of precancerous lesions and malignant tumors in the upper gastrointestinal tract.Results:After PSM, 1 655 subjects were included in both groups. In terms of lesion location, the detection rate of gastric body lesions in the anesthesia group was higher than that in the general group ( P<0.05), and the detection rate of esophageal lesions in the anesthesia group was lower than that in the general group ( P<0.05); In terms of lesion types, the detection rate of precancerous lesions such as gastric polyps, mucosal protrusions, mucosal atrophy, and intestinal metaplasia in the anesthesia group was higher than that in the general group (all P<0.05). The results of logistic regression analysis showed that intravenous anesthesia was an independent influencing factor for the detection rate of precancerous lesions and malignant tumors in diagnostic gastroscopy ( OR=1.338, 95% CI: 1.070-1.674, P<0.05). Conclusions:Intravenous anesthesia is an independent influencing factor for the detection rate of precancerous lesions and malignant tumors in diagnostic gastroscopy, and can improve the detection rate of upper gastrointestinal lesions.

18.
Chinese Journal of Endemiology ; (12): 675-678, 2023.
Article in Chinese | WPRIM | ID: wpr-991692

ABSTRACT

Objective:To analyze the external quality control assessment results of urinary iodine, salt iodine and water iodine in iodine deficiency disorders laboratories in Qinghai Province, to evaluate the testing capacity of provincial, municipal and county-level laboratories and the operation of external quality control network, so as to provide quality assurance for consolidating and eliminating iodine deficiency disorders.Methods:In 2021, 1 provincial, 8 municipal, and 43 county-level laboratories in Qinghai Province had participated in the assessment of urinary iodine and salt iodine, while 1 provincial and 8 municipal-level laboratories had participated in the assessment of water iodine. The assessment results were evaluated using the method of reference value ± uncertainty of external quality control samples.Results:All laboratories that participated in the assessment had provided feedback. One provincial-level laboratory passed the assessment of urinary iodine, salt iodine, and water iodine. Among 8 municipal-level laboratories, 2 laboratories failed the urinary iodine assessment, with a pass rate of 6/8; the assessment of salt iodine and water iodine in 8 laboratories were all qualified. Among 43 county-level laboratories, 7 laboratories failed the urinary iodine assessment, with a pass rate of 83.7% (36/43); the assessment of salt iodine in 43 laboratories were all qualified.Conclusions:The external quality control network of iodine deficiency disorders laboratories in Qinghai Province has fully covered all municipal and county-level laboratories. The testing capability of provincial-level laboratory is stable and maintains a high level; the testing quality of some municipal and county-level laboratories is still unstable and needs to be further strengthened.

19.
Chinese Journal of Endemiology ; (12): 65-68, 2023.
Article in Chinese | WPRIM | ID: wpr-991580

ABSTRACT

Objective:To learn about the detection quality and external quality control assessment of fluoride and arsenic in laboratories at all levels in Qinghai Province.Methods:The Z-score method was used to analyze and evaluate the evaluation results of 1 provincial, 8 municipal and 43 county level laboratories of disease prevention and control institutions participating in the external quality control assessment of water fluoride and brick tea fluoride in Qinghai Province in 2021, as well as 1 provincial, 1 municipal and 2 county level laboratories of disease prevention and control institutions participating in the external quality control assessment of water arsenic and urine arsenic. The feedback rate and qualification rate of external quality control of each assessment laboratory were calculated.Results:In 2021, the feedback rate of external quality control of water fluoride, brick tea fluoride, water arsenic and urine arsenic in provincial and municipal level laboratories of Qinghai Province were 100.00%; except that the qualified rate of water fluoride was 7/9, the qualified rate of external quality control of other projects was 100.00%. The feedback rate of external quality control of water fluoride, brick tea fluoride, water arsenic and urine arsenic in county level laboratories was 100.00%; except that the qualified rate of water fluoride was 86.05% (37/43), the qualified rate of external quality control of other projects was 100.00%. In the specific assessment results of the laboratory, the assessment results of water fluoride sample FS20210101 from 1 provincial, 1 municipal and 2 county level laboratories, and FS20210102 from 1 county level laboratory were suspicious; the assessment results of water fluoride sample FS20210101 from 3 county level laboratories were not satisfactory; the assessment results of fluoride and arsenic sample in other laboratories were satisfactory.Conclusions:The qualified rate of external quality control of fluoride and arsenic in laboratories at all levels in Qinghai Province is relatively high, but some county level laboratories are still dissatisfied with the assessment results of water fluoride. Therefore, it is necessary to strengthen the detection level of water fluoride in laboratories.

20.
Chinese Journal of Radiological Health ; (6): 668-672, 2023.
Article in Chinese | WPRIM | ID: wpr-1006325

ABSTRACT

Objective To test and analyze the performance of Biograph Vision 600 PET/CT according to the NEMA NU2—2012 standard to achieve reliable, repeatable, and inter-system comparable performance measurement, and to provide a basis for future equipment stability testing and status detection. Methods The Biograph Vision PET equipment features a detector based on silicon photomultipliers, with 3.2 mm lutetium oxyorthosilicate crystals and full cover of the scintillation region. The spatial resolution, sensitivity, noise-equivalent count rate, scatter fraction, coincidence count rate, image quality, scatter correction, and time-of-flight resolution of Biograph Vision PET were tested by referring to the test model and method of the NEMA NU2—2012 standard. Results The Biograph Vision 600 PET equipment showed lateral and axial spatial resolutions of 3.69 mm and 3.81 mm at 1 cm off-center of the field of view, respectively and of 4.29 mm and 4.48 mm at 10 cm, respectively. The sensitivity was 17.5 kcps/MBq. The time-of-flight resolution changed from 210 ps to 215 ps as the count rate increased to the peak noise equivalent count rate. The NEMA peak noise-equivalent count rate was 247 kcps at 30.3 kBq/ml. The corresponding scatter fraction was 34.8%. With the NEMA module, the overall image quality contrast range was 73.6%-92.8%, and the background variability was 2.3%-6.5%; the mean lung residual error was 3.4%; and the time-of-flight resolution was 210 ps. Conclusion This performance test was performed according to the NEMA NU2—2012 standard, showing that all parameters were better than the ex-factory standard, which can provide a reference for other institutions selecting equipment and also provide a basis for future equipment stability testing and status detection.

SELECTION OF CITATIONS
SEARCH DETAIL